Memenuhi Segala Kebutuhan Instrumentasi Anda - Cole Parmer - Polyscience - MMM - Macherey Nagel - Thermo Orion

» »

#1 of 2 | prev product Prev - Next next product
printer email

product arrow Orion* 4-Star Plus pH/ISE Benchtop Multiparameter Meter

Image   1

Orion* 4-Star Plus pH/ISE Benchtop Multiparameter Meter

  • Thermo Scientific* benchtop pH/ISE multiparameter meter with advanced accuracy and reliability for R&D and QA/QC applications.
  • Measures pH and concentraion with the accuracy and reliability you need for ISE measurements

Part Number Description
1115000 Orion 4-Star Plus pH/ISE Meter Only
1115001 Orion 4-Star Plus pH/ISE Meter Kit (includes ROSS pH electrode, ATC probe, electrode stand, buffers and storage solution)
1115002 Orion 4-Star Plus pH/ISE Meter Kit (includes Sure-Flow pH electrode, ATC probe, electrode stand, buffers and storage solution)
1115003 Meter Kit/pH 1115003
1115004 Meter Kit/pH 1115004

Specifications
Model Orion 4-Star Plus pH/ISE Benchtop Multiparameter Meter
pH Mode
Range -2.000 to +19.999pH
Resolution 0.1/0.01/0.001pH
Relative Accuracy ±0.002pH
Calibration Points AUTO-CAL* and/or Manual Calibration; 1 to 5 points; US/NIST, DIN, and custom buffers recognized
ISE Mode
Range 0 to 19,999 in M, mg/L, %, ppb, or no units
Resolution 1, 2, or 3 signi?cant digits
Relative Accuracy ±0.2mV or 0.05%, whichever is greater
Calibration Poin 1 to 5 points; linear point to point, non-linear selectable auto-blank, low concentration range options
mV/RmV/ORP Mode
Range ±1999.9mV
Resolution 0.1mV
Relative Accuracy ±0.2mV or 0.05%, whichever is greater
ORP Calibration EH autocalibration to standard hydrogen electrode for ORP measurements
Temperature Mode
Range -5° to +105°C
Resolution 0.1°C up to 99.9°C, 1.0 over 99.9°C
Relative Accuracy ±0.1°, ±1 digit
Temperature Compensation Automatic or manual, -5° to +105°C
Display Custom LCD; simultaneous display of selected measurement and temperature, pH calibration points, and current electrode condition
Inputs/Outputs
Inputs BNCBNC for pH/ORP/ISE electrodes; 8-Pin Mini-DIN Locking for ATC probe; Pin tip for separate reference electrode; Phono jack for stirrer
Sensor Types pH, ORP or Ion Selective Electrodes
Outputs Bidirectional RS-232, stereo jack, optional USB interface cable
Data Management GLP Electrode Veri?cationSaves 10000 points by time, stability or manual read with time/date stampCalibration log of last 10 calibrationsUser method storage for 10 proceduresAdvanced self-test and diagnostics routinesPassword protectionDownloadable software and methods updates via Internet
GLP Compliance 21 CFR Part II Compliant with optional software
Regulatory and Safety Compliance CE, CSA, UL, TUV, FCC Class A limits
Environmental Operating Conditions
Ambient Operating Temperature 5° to 45°C
Relative Humidity 5 to 85% noncondensing
IP Rating IP54 compliance: splashproof and dustproof
Stability SMART STABILITY* and SMART AVERAGING*: Resolution dependent/automatic
Power Supply Universal AC power adapter or 4 x 1.5V AA (optional)
Warranty Three years from date of purchase